5083 sensitization risk checker

Estimate β-phase sensitization risk from alloy, starting temper, service temperature and time at temperature.

risk safe time → temperature → ~65 °C threshold

Alloy and temper




Service conditions




FormulaHow the risk band is scored

Sensitization is magnesium migrating to the grain boundaries as β-phase (Mg2Al3) when 5xxx plate sits in a critical temperature band. The screen combines a base rate, a temper factor and time at temperature.

Risk = base(alloy) × temper factor × temperature factor × time factor

Temperature bandEffect on 5xxx
Below 65 °CNo practical sensitization
65 – 200 °CSensitization band — avoid prolonged exposure
Above 200 °Cβ-phase re-dissolves; not the sensitizing range
Peak around 100 – 150 °CFastest β-phase precipitation
The certified route out of sensitization risk is the H116 / H321 temper — both are specified with a maximum sensitization test value under ASTM G67, which is why marine plate is bought in those tempers.
TipsPractical notes
  • Never let 5083 H116 plate sit in the 65–200 °C band for long. Insulated engine rooms and exhaust-adjacent structure are the usual offenders.
  • If a repair needs heating, keep the affected area below the band or re-solution-treat; a torch pass at 120 °C is the classic way to create a problem.
  • For LNG and cryogenic service, H116 / H321 are the specified tempers and the mill test reports carry a G67 result.

People also ask

What does sensitization actually do?

Magnesium leaves solution and forms β-phase (Mg2Al3) along grain boundaries. The boundary becomes anodic and the plate loses resistance to intergranular corrosion and stress-corrosion cracking.

Why is 5083 H116 the marine standard?

The H116 temper is specified with a maximum ASTM G67 mass-loss value, so it is proven not sensitized as delivered. H321 has a similar guarantee for heavier plate.

Does welding sensitize the plate?

A normal weld pass is fine — it is above the band and re-dissolves β-phase. The risk is long, slow heating in the 65–200 °C range, not a quick weld.

Can sensitized plate be recovered?

Yes, by a full solution treatment above 400 °C followed by the correct temper. In practice this is a mill operation, not a yard one.

How is sensitization tested?

ASTM G67 nitric acid mass-loss test is the standard for 5xxx plate. A value under 15 mg/cm² generally passes; higher indicates sensitization.

Does 5052 or 5754 sensitize?

Far less. Their magnesium content is lower (about 2.5–3.5%), so there is less solute to precipitate. The issue is concentrated in the 4.5% Mg and above grades.

Need plate to match these numbers?

Reply in one working day with stock availability and a firm price.

Related tools